RT Series 5/6/8/10/15/20 kVA

RT Series 5/6/8/10 kVA Single Phase UPS, 10/15/20 kVA Three Phase UPS

A total solution for reliable power with high availability and performance

The Amplon RT Series 5-20 kVA is an online double-conversion UPS that provides best-in-class designs in compact 2U size, high power density, system efficiency, and versatile configurations to fulfill customers' requirements. Unity output power factor maximizes capacity for more critical loads, while outstanding energy savings can be achieved based on the AC-AC efficiency of up to 96.5% and 99% in ECO mode. In addition, RT Series 5-20 kVA UPS is the first in the market that offers standard Li-ion external battery cabinets, which deliver better power density and sustainability. Along with the parallel capacity of up to four units, the new series is the ideal small power UPS for mission-critical applications, such as servers, data centers, telecommunications, and manufacturing.
 


 

 

Product available regions:
Because product specifications vary slightly from region to region, please download your local leaflet or visit your local website for detailed product information.
EMEA North America South America SEA India China Taiwan South Korea

Ext, Std, 3P

208V

Ext, 3P

Ext, Std, 3P

Ext, 3P

Ext, 3P

208V, 3P

Ext. 3P


Ext: RT 5-10 kVA Extended Runtime Model
Std: RT 5-10 kVA Standard Runtime Model
208V: RT 5-10 kVA, 208 V
3P: RT 10-20 kVA, 3-Phase



Request a Quote Subscribe Newsletter

Product Introduction

Features & Benefits

Availability & Flexibility

  • True online double-conversion topology and zero transfer time to battery provides 24/7 full-time protection
  • Wide input voltage range allows the UPS to operate in harsh electrical environments and extends battery life
  • AC-start function allows the UPS to be switched on without connecting to a battery
  • Programmable load bank disconnects non-critical loads when a blackout occurs and reserves more battery power for critical loads
  • Up to four units parallel capacity allows redundancy and load expansion  (Apply to 5-10kVA)
  • Hot swappable batteries ensure continuous operation even when batteries are being replaced
  • VRLA and Li-ion External Battery Cabinet (EBC) are available for scalable runtime
  • Flexible battery quantity configuration enables optimized battery investment. And when one battery fails, it could be removed without replacing the entire battery string, reducing maintenance cost and efforts
  • The Power Distribution Box (PDB) and Maintenance Bypass Breaker (MBB) are optional respectively for easy configuration and easy UPS replacement
  • The rRPP (Rack Remote Power Panel), which can be integrated with standard server racks, simplifies power output distribution and power monitoring
  • Common battery configuration is supported in RT 15/20kVA parallel mode to save installation space and additional battery costs
 

Efficiency & Reliability

  • Unity output power factor guarantees no de-rating with loads and provides permanent 100% kW
  • Best-in-class AC-AC efficiency of up to 96.5% and 99% in ECO mode lowers energy costs
  • Automatic fan speed control maximizes system efficiency and significantly reduces audible noise and prolongs battery life
  • Fan failure detection sends early warnings to facilitate predictive maintenance of UPS
 

Manageability

  • Intelligent battery management to extend battery life and maximize battery performance. The battery aging detection monitors battery status for predictive maintenance, and the 3-stage charging mechanism keeps the battery from continuous float charging during the intermission stage to prolong battery life
  • Excellent local management through a user-friendly graphical and multi-lingual LCD display
  • Various types of communication interfaces, including USB, RS-232, and RS-485 ports, mini slot, REPO/ROO for remote management, and in-built dry contacts for monitoring and notification of system operation conditions
  • UPS management software such as ShutdownAgent and InfraSuite Device Manager allow users to monitor UPS status and protect critical devices
Applications

Specifications
  1. Model
  2. Single Phase: RT-5K / RT-6K / RT-8K / RT-10K
    Three Phase: RT-10K3P / RT-15K3P / RT-20K3P

  3. Power Rating
  4. RT-5K: 5 kVA / 5 kW
    RT-6K: 6 kVA / 6 kW
    RT-8K: 8 kVA / 8 kW
    RT-10K: 10 kVA / 10 kW
    RT-10K3P: 10 kVA / 10 kW
    RT-15K3P: 15 kVA / 15 kW
    RT-20K3P: 20 kVA / 20 kW

  5. Input
  6. Voltage Range - RT-5K/6K/8K/10K:
    100~280 Vac (Single phase, 2-wire + G)
    100~175 Vac with linear de-rating 50~100%
  7. Voltage Range - RT-10K3P/15K3P/20K3P:
    138~485 Vac (Three phase, 4-wire + G)
    138~305 Vac with linear de-rating 40~100%
  8. Frequency: 40~70 Hz
  9. Power Factor: > 0.99 (full load)
  10. iTHD: < 3%
  11. Input connection
    RT-5K/6K/8K/10K: Input terminal x 1
    RT-10K3P/15K3P/20K3P: Input terminal x 1, Bypass Input terminal x 1

  12. Output
  13. Power Factor: Unity
  14. Voltage
    RT-5K/6K/8K/10K: 200/208/220/230/240 Vac (Single phase)
    RT-10K3P/15K3P/20K3P: 380/400/415 Vac (Three phase), or 220/230/240 Vac (Single phase)
  15. Frequency: 50/60 Hz ±0.05 Hz
  16. Voltage Harmonic Distortion: ≤ 2% (linear load)
  17. Overload Capability - RT-5K/6K/8K/10K:
    ≤ 105%: continuous
    106~125%, 5 minutes
    126~150%, 1 minute
    > 150%: 500 ms
  18. Overload Capability - RT-10K3P/15k3P/20K3P:
    ≤ 105%: continuous
    106~125%: 2 minutes
    126~150%: 30 seconds
    > 150%: 200 ms

  19. Receptacle
  20. Standard Runtime Model
    RT-5K/6K: C13 x 6, C19 x 2, Terminal x 1, Load bank: C19 x 1
    RT-8K/10K: C13 x 6, C19 x 4, Terminal x 1, Load bank: C19 x 1
  21. Extended Runtime Model
    RT-5K/6K/8K/10K: Terminal x 1, Load bank: Terminal x 1
  22. Three Phase
    RT-10K3P/15K3P/20K3P: Terminal x 1

  23. Efficiency
  24. AC-AC
    RT-5K/6K/8K/10K: Up to 95.5%
    RT-10K3P/15K3P/20K3P: Up to 96.5%
  25. ECO Mode: Up to 99%

  26. Battery Voltage
  27. Standard Runtime Model
    RT-5K/6K: 192 Vdc
    RT-8K/10K: 240 Vdc
  28. Extended Runtime Model
    RT-5K/6K/8K/10K: 144 Vdc*, 192~264 Vdc
  29. Three Phase
    RT-10K3P: 144 Vdc*, 192~264 Vdc
    RT-15K3P/20K3P: ±144 Vdc*, ±192~±264 Vdc

  30. Charger Current
  31. Standard Runtime Model
    RT-5K/6K: 1 A (default)
    RT-8K/10K: 1.5 A (default)
  32. Extended Runtime Model
    RT-5K/6K/8K/10K: Up to 8 A
  33. Three Phase
    RT-10K3P/15K3P/20K3P: Up to 8 A

  34. Typical Backup Time (Run Time Table)
  35. Standard Runtime Model - 75% load
    RT-5K: 7.5 min
    RT-6K: 5.5 min
    RT-8K: 9 min
    RT-10K: 8 min
  36. Standard Runtime Model - Full load
    RT-5K: 5 min
    RT-6K: 3 min
    RT-8K: 5 min
    RT-10K: 3.5 min
  37. Extended Runtime Model
    RT-5K/6K/8K/10K: Depending on different configurations required by customers
  38. Three Phase
    RT-10K3P/15K3P/20K3P: Depending on different configurations required by customers

  39. Audible Noise
    RT-5/K6K: 48 dB
    RT-8K/10K/10K3P: 50 dB
    RT-15K3P/20K3P: 54 dB

  40. Display: Graphical and multi-lingual LCD

  41. Communication Interfaces: MINI Slot x 1, Parallel Port** x 2, USB Port x 1, RS232 Port*** x 1, RS485 Port x 1, REPO/ROO Port x 1, Dry Contact x 4

  42. Dimensions (W x D x H)
  43. Standard Runtime Model
    RT-5K/6K: 440 x 665 x 176 mm
    RT-8K/10K: 440 x 750 x 218 mm
  44. Extended Runtime Model
    RT-5K/6K: 440 x 430 x 88.2 mm
    RT-8K/10K: 440 x 565 x 88.2 mm
  45. Three Phase
    RT-10K3P: 440 X 649 X 88.2 mm
    RT-15K3P/20K3P: 440 x 760 x 88.2 mm

  46. Weight
  47. Standard Runtime Model
    RT-5K/6K: 54 kg
    RT-8K/10K: 85.5 kg
  48. Extended Runtime Model
    RT-5K/6K: 10.9 kg
    RT-8K/10K: 15.2 kg
  49. Three Phase
    RT-10K3P: 16.6 kg
    RT-15K3P/20K3P: 22.5 kg

  50. Environment
  51. Operating Temperature: 0~55°C****
  52. Relative Humidity: 5~95% (non-condensing)

  53. * De-rating to 70% load
    ** Only applicable to RT 5-10 kVA Extended Runtime Model and RT 15/20 kVA
    *** Not applicable to RT 15/20 kVA
    **** When the operating temperature is at 40~55°C, the UPS will be de-rated to 75% of its capacity

    All specifications are subject to change without prior notice.
     
Run Time
  1. Standard Model
  2. Power Rating Internal Battery External Battery Cabinet Quantity Run time at different load (mins)
    25% 50% 75% 100%
    5 kVA - 200/208V
    (UPS502R2RT0B0B8)
    Yes 0 35.6 15.6 8.9 5.6
    1 68.0 31.0 19.0 13.0
    2 106.0 51.0 32.0 22.6
    3 145.5 71.5 45.5 32.5
    4 185.0 91.5 59.0 42.5
    5 kVA - 220/230/240V
    (UPS502R2RT0B035)
    Yes 0 35.2 15.2 7.8 5.1
    1 61.0 27.0 16.5 11.0
    2 96.0 45.5 28.0 19.5
    3 131.0 63.5 40.0 28.5
    4 166.5 82.0 52.5 37.5
    6 kVA Yes 0 24.3 9.6 5.6 3.1
    1 50.0 22.0 13.0 8.5
    2 79.5 37.0 22.5 15.5
    3 109.0 52.0 32.5 22.5
    4 137.0 67.0 42.5 30.0
    8 kVA Yes 0 36.3 15.6 9.3 5.1
    1 71.0 27.0 14.5 9.6
    2 119.0 49.5 27.5 17.5
    3 167.5 73.5 42.5 27.5
    4 217.0 98.0 58.0 39.0
    10 kVA Yes 0 30.2 11.9 6.2 3.7
    1 53.0 19.4 10.5 7.4
    2 91.0 36.0 19.5 12.5
    3 130.0 54.8 30.5 19.5
    4 170.0 74.0 42.5 28.0
  3.  
  4. Extended Model
  5. Power Rating External Battery Cabinet P/N External Battery Cabinet (EBC) Quantity Run time at different load (mins)
    25% 50% 75% 100%
    5 kVA BBU161B107035 1 35.2 15.2 7.8 5.1
    2 61.0 27.0 16.5 11.0
    3 96.0 45.5 28.0 19.5
    4 131.0 63.5 40.0 28.5
    BBU201B109035 1 50.0 18.5 10.3 7.3
    2 123.5 53.2 30.0 19.3
    3 199.5 91.0 54.2 36.0
    4 276.4 130.0 79.5 54.5
    6 kVA BBU161B107035 1 24.3 9.6 5.6 3.1
    2 50.0 22.0 13.0 8.5
    3 79.5 37.0 22.5 15.5
    4 109.0 52.0 32.5 22.5
    BBU201B109035 1 39.0 14.2 8.2 6.0
    2 100.5 41.4 22.5 14.5
    3 164.4 72.5 42.0 27.5
    4 228.5 105.0 63.0 42.5
    8 kVA BBU201B109035 1 36.3 15.6 9.3 5.1
    2 71.0 27.0 14.5 9.6
    3 119.0 49.5 27.5 17.5
    4 167.5 73.5 42.5 27.5
    10 kVA BBU201B109035 1 30.2 11.9 6.2 3.7
    2 53.0 19.4 10.5 7.4
    3 91.0 36.0 19.5 12.5
    4 130.0 54.8 30.5 19.5

    15 kVA

    BBU201B109035 1 set (2 EBC) 39.3 16.8 10.0 6.8
    2 set (4 EBC) 90.5 41.1 25.0 17.2
    3 set (6 EBC) 143.1 67.4 41.9 29.2
    4 set (8 EBC) 196.1 94.3 59.7 42.1
    BBU161B107035 1 set (2 EBC) 16.4 7.1 4.0 2.3
    2 set (4 EBC) 39.3 17.6 10.6 7.4
    3 set (6 EBC) 63.5 29.5 17.9 12.5
    4 set (8 EBC) 88.2 41.9 25.8 18.2
    Li-ion battery :
    GES021B704035 + 099114191A
    1 set (2 EBC) 24.0 10.8 8.1 5.8
    20 kVA BBU201B109035 1 set (2 EBC) 27.5 11.5 6.8 4.4
    2 set (4 EBC) 65.1 28.7 17.2 11.8
    3 set (6 EBC) 104.4 47.8 29.2 20.2
    4 set (8 EBC) 144.3 67.7 42.1 29.3
    BBU161B107035 1 set (2 EBC) 11.6 4.8 2.3 1.3
    2 set (4 EBC) 28.3 12.3 7.4 4.6
    3 set (6 EBC) 46.4 20.7 12.5 8.6
    4 set (8 EBC) 65.1 29.8 18.2 12.5
    Li-ion battery :
    GES021B704035 + 099114191A
    1 set (2 EBC) 18.6 8.9 5.8 3.6
 
 

Rear Views

 

 

 

 

RT 5/6/8/10 kVA

 
 

 

EMEA, SEA

Amplon RT 5/6/8/10 kVA - rear views for EMEA, SEA

 

 

South America, India, Taiwan, Korea

Amplon RT 5/6/8/10 kVA extended model UPS rear views for all regions

 

 

China

Amplon RT 5/6/8/10 kVA UPS rear views for China

 

 

North America

Amplon RT 5/6/8/10 kVA UPS rear views for North America

 

 

RT 15/20 kVA

For all available regions

Amplon RT 15/20 kVA UPS rear view

 
Download

RT Series 5/6/8/10/15/20 kVA UPS (Leaflet) / 808 KB
for EMEA, SEA (English): Extended Runtime Model & Standard Runtime Model

 

RT Series 5/6/8/10/15/20 kVA UPS (Leaflet) / 810 KB
for China, India, Korea, South America (English): Extended Runtime Model

 

RT Series 5/6/8/10 kVA UPS 208V (Leaflet) / 1.35 MB
for North and South America (English)

 

RT Series 5/6/10 kVA UPS 208V (Leaflet) / 388 KB
for Taiwan (Traditional Chinese)

 

RT Series 10/15/20 kVA UPS, 3-phase (Leaflet) / 388 KB
for Taiwan (Traditional Chinese)

 

RT Series 5/6/8/10 kVA UPS (User Manual) / 10.4 MB
- Standard Runtime Model

 

RT Series 5/6/8/10 kVA UPS (User Manual) / 9.68 MB
- Extended Runtime Model

 

RT Series 10/15/20 kVA 3P UPS (User Manual) / 5.91 MB

 

RT Series 10/15/20 kVA UPS - Maintenance Bypass Box for Single UPS (User Manual) / 2.31 MB

 

RT Series 10/15/20 kVA UPS - Power Distribution Box for Single UPS, Parallel UPSs / 3.73 MB

 

RT Series 5/6/8/10/15/20 kVA UPS (Quick Guide)- External Battery Pack / 1.79 MB

 

RT Series 5/6/8/10 kVA UPS (Quick Guide)- Maintenance Bypass Box / 3.88 MB

 

RT Series 5//6/8/10/11/15/17/20 kVA UPS - Lithium-ion Battery Pack (User Manual) / 2.22 MB

 

Rack-Mount Remote Power Panel, 40kVA (Quick Guide) / 13.00 MB
English, SImplified Chinese, Traditional Chinese

 


Request a Quote Subscribe Newsletter