Modular UPS: DPH Series 20 - 80/120 kVA

The next generation of modular UPS systems designed for ultimate availability,excellent performance, high efficiency, and ideally suited for medium-sizeddatacenters.

In this IT intensive world with heavy data traffic driven by cloud, 4G/5G and media streaming applications, IT managers are facing the challenges of increasing rack power density and limited data center space. Delta's innovative modular UPS technologies provide the answer to customers' demands for ultimate availability, excellent performance, and high efficiency. The brand-new Delta Modulon DPH series UPS 80/120 kVA achieves the industry's leading power density of 20kW per module in 2U height, offering the smallest footprint and best space utilization. The Modulon DPH Series UPS is the ideal modular power protection for all critical IT applications with its small package, flexibility and seamless integration.

UPS DPH Series 20-120kVA - features

Product available regions :
Because product specifications vary slightly from region to region, please download your local leaflet or visit your local website for detailed product information.

EMEA North America South America SEA India China Taiwan South Korea
 


Request a Quote Subscribe Newsletter

Product Introduction

Features & Benefits

Excellent Power Performance

  • The industry's leading power technology offers up to 120 kW within all equipped breakers in 162.8 kW/m3 which supports the top/bottom cable entry without additional cabinet to achieve the best utilization compared with its peers
  • High AC-AC efficiency over 96% and ECO mode to 99% resulting in marked energy cost savings
  • Green mode featuring a load aggregation function optimizes system efficiency
 

Ultimate Availability

  • Fully modularized design and hot-swappable key modules ensure Mean Time To Repair (MTTR) close to zero without downtime risk
  • Redundant components and dual CAN bus delivers highest system availability and avoids single point of failure
  • Key components aging pre-warning mechanism provides proactive reliability to minimize human error and reduce downtime risk (optional)
 

High Manageability

  • User-friendly 10" color touch screen enables easy local UPS management
  • Environment information such as temperature, humidity and transmitting signals from environment sensors can be integrated into the UPS for easy monitoring via the LCD of the UPS
  • If the UPS is equipped with an external battery management system, the battery information can be integrated into the UPS and monitored via the LCD of the UPS
Specifications
  1. Model
  2. DPH-80K / DPH-120K

  3. Power Rating
  4. DPH-80K
    20, 40, 60, 80 kVA
    20, 40, 60, 80 kW
    Power Module Quantity: Up to 4 units
  5. DPH-120K
    20, 40, 60, 80, 100, 120 kVA
    20, 40, 60, 80, 100, 120 kW
    Power Module Quantity: Up to 6 units

  6. Input
  7. Nominal Voltage: 220/380 Vac, 230/400 Vac, 240/415 Vac (3-phase, 4-wire + G)
  8. Voltage Range: 305~478 Vac (full load), 228~478 Vac (70% load)
  9. Current Harmonic Distortion: ≤ 2% *
  10. Power Factor: > 0.99
  11. Frequency Range: 50/60 Hz

  12. Output
  13. Voltage: 220/380 Vac, 230/400 Vac, 240/415 Vac (3-phase, 4-wire + G)
  14. Voltage Harmonic Distortion: ≤ 1% (linear load); ≤ 4% (non-linear load)
  15. Voltage Regulation: ± 1% (static)
  16. Frequency: 50/60 Hz
  17. Overload Capability: ≤ 125%: 10 minutes; ≤ 150%: 1 minute; > 150%: 1 second

  18. Display: 10” color touch screen

  19. Interface
  20. Standard
    External battery temperature detection x 4, External switch/breaker status dry contact x 4, Output dry contact x 6, Input dry contact x 4, Parallel port x 2, USB Port (Type A x 2; Type B x 1), RS232 Port x 1, Modbus Port x 1, BMS (RJ45) x 1, Ethernet x 1, SNMP Slot x 1, REPO Port x 1

  21. Conformance
  22. Safety: CE (IEC62040-1, IEC62040-2 (C3: standard, C2: optional)

  23. Efficiency
  24. AC-AC: > 96% (Peak efficiency)
    ECO Mode: 99%

  25. Battery
  26. Nominal Voltage: ± 240 Vdc (default, ± 180 Vdc ~ ± 276 Vdc configurable)
  27. Charge Voltage: ± 272 Vdc (adjustable from 204 V to 312 V)
  28. Protection of Battery Deep Discharge: Yes

  29. Environment
  30. Operating Temperature: 0~40℃
  31. Relative Humidity: 95% (non-condensing)
  32. Audible Noise (at one meter): < 65 dB
  33. IP Protection: IP20

  34. Others
  35. Parallel Redundancy and Expansion: Module and system redundancy, Maximum 8 units
  36. Battery Start: Yes

  37. Physical
  38. Dimensions (W x D x H): 600 x 850 x 1445 mm
  39. Weight - UPS System (without power modules)
    DPH-80K: 150 kg
    DPH-120K: 162 kg
  40. Weight - 20 kW Power Module (optional): 18 kg

  41. * When input voltage total harmonic distortion input is less than 1%

    All specifications are subject to change without prior notice.