DPS Series 160-500 kVA

From 160 to 500 kVA, scalable up to 4000 kVA in parallel

Delta's Ultron DPS is a double-conversion and IGBT-rectifier three phase UPS. With the three level IGBT topology for both PFC (power factor correction) and inverter, the Ultron DPS features industry leading performance of up to 96% AC-AC efficiency. Thanks to Delta's advanced digital PFC control, it also has low iTHD < 3% and high input power factor > 0.99 resulting in significant total cost of ownership (TCO) savings. Aiming to achieve the highest availability possible, Delta has enhanced special designs for battery management, swappable fans and ease of maintenance.To empower customers to make the optimal choice for their unique energy needs, the Ultron DPS series includes three different cabinet sizes: 160 kVA UPS~200 kVA UPS ; 300 kVA UPS~500 kVA UPS.

Excellent power performance and high system availability of the Ultron DPS provide customers with the benefits of a stable power supply, high power efficiency, low capital investment and low overall operation cost. To increase system reliability in the challenging electrical environments common for today's businesses, Delta has designed the Ultron DPS with an input voltage range -40% ~ +20%, for clients looking to build a foundation on a N+X redundancy / hot-standby configuration. Intelligent fan speed control and redundant fan design that prevents overheating is also featured in the Ultron DPS.

With its state-of-art design, intelligent fan speed control and redundant fan design, Delta's Ultron DPS UPS series provides a cornerstone for power performance and efficiency.

Control and LCD Display Panel, InsightPower Manager
Product available regions :
Because product specifications vary slightly from region to region, please download your local leaflet or visit your local website for detailed product information.

EMEA North America South America SEA India China Taiwan South Korea
 


Request a Quote Subscribe Newsletter

Product Introduction

Features & Benefits

High Reliability

  • N+X redundancy or hot-standby configuration ensures increased system reliability
  • Wide input voltage ranges (DPS 160 kVA~500 kVA : -40% ~ +20%) allows the UPS to work at optimal performance levels even in harsh electrical environments
  • Field programmable sequential start-up reduces the impact on the generator
  • Intelligent fan speed control and redundant fan design prevent UPS from overheating and increase overall system reliability
  • Parallel link functionality improves the stability of the output load, keeping the output load stable and the flow of power uninterrupted in the event of failure by a single UPS


 

Reduced Total Cost of Ownership

  • High AC-AC efficiency even at light load levels reduces energy loss and lowers ongoing operating costs
  • High input power factor (> 0.99) and low input harmonic distortion (iTHD < 3%) eliminate the need to oversize the genset, reducing initial capital investment


 

High Flexibility

The Delta Ultron DPS series includes models with full power ratings ranging from 160 kVA to 500 kVA in a single device, scalable up to 4000 kVA when used in parallel. The extensive range of possible power ratings ensures a match for specific application requirements.

There are three different cabinet sizes available as part of the Ultron DPS series. The optimal power density and compact design of each cabinet enables end-users to conserve valuable space. The light weight of every cabinet size reduces transportation and installation costs.

Parallel expansion of the Ultron DPS series UPSs up to 4000 kVA without extra hardware allows for quick capacity upgrades to keep pace with the changing power needs of growing businesses.

 

Common batttery configuration of Ultron DPS in parallel mode can support customers to:
 
  • Significantly save installation space and lower rent expenses
  • Reduce additional investment in batteries
  • Make UPS expansions easier without the need for additional battery investments
  • Lower the cost of possible floor loading enhancement


 

Easy Maintenance

  • Hot-swappable fans reduce m
  • aintenance lead time (applicable for 160 kVA UPS through 500 kVA UPS models)
  • Built-in manual bypass allows zero downtime and ensures system availability even during service maintenance
  • Main I/P and O/P switches detection provide quick diagnosis when faults occur


 

Intelligent Battery Management

Delta’s intelligent battery management system can maximize and sustain the lifespan of batteries, and efficiently utilize the capacity of any backed-up battery due to the following functions:
 
  • Battery temperature monitoring & compensation
  • Battery remaining capacity displayed in percentage
  • Protection against overcharge and discharge
  • Boost/float stage charge
  • Auto or manual battery test
  • 38~42 battery units in one battery cabinet optimizes investment (applicable for 160 kVA UPS through 500kVA UPS models)
Applications

Specifications
  1. Model
  2. DPS-160K / DPS-200K / DPS-300K / DPS-400K / DPS-500K

  3. Power Rating
  4. DPS-160K: 160 kVA / 144 kW
    DPS-200K: 200 kVA / 180 kW
    DPS-300K: 300 kVA / 270 kW
    DPS-400K: 400 kVA / 360 kW
    DPS-500K: 500 kVA / 450 kW

  5. Input
  6. Nominal Voltage: 380/220 Vac, 400/230 Vac, 415/240 Vac (3 phase, 4-wire + G)
  7. Voltage Range: 324~477 Vac (full load), 242~324 Vac (70~100% load)
  8. Current Harmonic Distortion: < 3% *
  9. Power Factor: > 0.99
  10. Frequency: 45~65 Hz

  11. Output
  12. Voltage: 380/220 Vac, 400/230 Vac, 415/240 Vac (3 phase, 4-wire + G)
  13. Output Power Factor: 0.9 (standard); 1 (optional) **
  14. Voltage Harmonic Distortion: ≤ 1.5% (linear load); < 1% (linear load) **
  15. Voltage Regulation: ± 1% (static)
  16. Frequency: 50/60 Hz ± 0.05 Hz
  17. Overload Capability: ≤ 125%: 10 minutes; ≤ 150%: 1 minute

  18. Display: Mimic LCD supports multi-language and LED indicators

  19. Communication Interfaces
  20. Standard: RS232 x 1, Smart slot x 2, Output dry contact x 6, Input dry contact x 7, (Input dry contact (two sets), REPO x 1, External battery cabinet status detection x 1, External battery cabinet temperature detection x 4), Parallel port x 2, USB port x 1

  21. Conformance
  22. Safety & EMC: CE, RCM

  23. Other Features
  24. Parallel Redundancy: Up to 8 units
  25. Emergency Power Off: Local and remote
  26. Event Log: 500 records

  27. Efficiency
  28. AC-AC: Up to 96%
  29. ECO Mode: Up to 99%

  30. Environment
  31. Operating Temperature: 0~40°C
  32. Relative Humidity: 0~95% (non-condensing)
  33. Audible Noise
    DPS-160K/200K: < 70 dBA
    DPS-300K/400K: < 73 dBA
    DPS-500K: < 76 dBA
  34. IP Protection: IP20

  35. Physical
  36. Dimensions (W x D x H)
    DPS-160K/200K: 850 x 865 x 1950 mm
    DPS-300K/400K/500K: 1600 x 865 x 1950 mm
  37. Weight
    DPS-160K/200K: 697 kg
    DPS-300K/400K: 1200 kg
    DPS-500K: 1220 kg

  38. * When input harmonic distortion is less than 1%.
    ** Available in South East Asia, Australia and New Zealand.

    All specifications are subject to change without prior notice.
Download

DPS 160/200/300/400/500 kVA UPS (Leaflet) / 361 KB
for all available regions excluding North American and Taiwan (English)

 

DPS 200/400/500 kVA UPS (Leaflet) / 497 KB
for Taiwan (Traditional Chinese)

 

DPS 160/200 kVA UPS (User Manual) / 5.43 MB

 

DPS 300/400/500 kVA UPS (User Manual) / 28 MB

 


Request a Quote Subscribe Newsletter