DVS-109W02-1GE

DVS-109W02-1GE2020-10-07T06:21:22+00:00

Specifications

Technology
Standard Compliance

  • EEE 802.3 10Base-T
  • IEEE 802.3u 100Base-T(X) and 100Base-FX
  • IEEE 802.3ab 1000Base-T
  • IEEE 802.3x Flow Control
  • IEEE 802.1D Spanning Tree Protocol
  • IEEE 802.1w Rapid Spanning Tree Protocol
  • IEEE 802.1s Multiple Spanning Tree Protocol
  • IEEE 802.1p Class of Service, Priority Protocols
  • IEEE 802.1Q VLAN Tagging
  • IEEE 802.1X Port Authentication
  • IEEE 802.3ad LACP Aggregation
  • IEEE 802.1AB Link Layer Discovery Protocol

Processing Type
Store and Forward

  • IEEE 802.3x Flow control in full duplex, back-pressure flow control in half duplex

Interface
Fast Ethernet

  • RJ45 Ports: 8 10/100Base-T(X), auto MDI/MDI-X, auto negotiation

Gigabit Ethernet

  • RJ45 Ports: 1 10/100/1000Base-T, auto MDI/MDI-X, auto negotiation

Console Port

  • USB B-Type connector
  • Digital Input(DI)
  • 1 set
  • 0~+5V is OFF
  • +11V~30V is ON
  • Max. input current 6mA

Alarm Contact(DO)

  • 1 relay output
  • Carry current 2A@24VDC

Reset Button

  • 1set

Performance and Scalability

  • Switching Capacity: 3.6Gbps, wired-speed, non-blocking switching fabric
  • Forwarding Rate: 5.35Mpps
  • MAC Address Table: 8K
  • Packet Buffer Memory: 512K bits
  • IGMP Multicast Groups: 256
  • Max. VLANs: 255
  • Quality of Service: 8 priority queues per port
  • DHCP/BootP Server: 1275 IP addresses
  • Jumbo Frame: 9,216 Bytes

Management

  • Software: STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/v2/v3, IGMP Query v1/v2, GARP, GMRP, VLAN, SSH, DNS, HTTP, HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP Traps, TFTP, RMON, LLDP, BootP Server/Client, DHCP Server/Client, DHCP L2 Relay, DHCP Relay Option 82, DHCP Option 66/67, Telnet, Syslog, SMTP, SNTP Server/Client, IPv6, MODBUS TCP, EtherNet/IP
  • Security: MAC/IP/TCP/UDP filtering, HTTPS, SSH, 802.1x, TACACS+, SNMP v3
  • Configuration: Web Browser, Cisco-like Telnet CLI, USB Local Console , SNMP, MODBUS TCP, EtherNet/IP, IEXplorer Utility
    MIB: MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/P-Bridge MIB, IF MIB, Traceroute MIB, TCP MIB, UDP MIB, IP MIB, RMON Group 1,2,3,9, Delta Private MIB

Power Requirements

  • Input Voltage: 2 sets, 12 to 48VDC redundant terminal block input
  • Input Current: 0.58A Max.
  • Overload Current Protection: Present, Max. input current 3A
  • Reverse Polarity Protection: Present
  • Buffer Time: Min. 12ms at 24VDC

Physical

  • Housing : IP40 metal case
  • Dimensions : 145.3 mm(H) x 75 mm(W) x 108.7 mm (D)
  • Weight : 500g
  • Installation : Industrial DIN-Rail and wall mounting

Environmental Limits

  • Operating Temperature : -40℃ to 75℃(-40°F to 167°F)
  • Storage Temperature: -40℃ to 85℃(-40°F to 185°F)
  • Ambient Relative Humidity: 5% to 95%(non-condensing)

Approvals

  • Safety: UL 508, EN 60950-1, IEC 61131-2
  • EMI: FCC 47 CFR Part 15 Subpart B Class A, IEC 61000-6-4, EN 55022
  • EMS(IEC 61000-6-2): IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, IEC 61000-4-4 level 4, IEC 61000-4-5 level 3, IEC 61000-4-6 level 3, IEC 61000-4-8 level 4, IEC 61000-4-29

Environmental Type Tests:

  • Cold Temperature: IEC 60068-2-1
  • Dry Heat: IEC 60068-2-2
  • Humidity: IEC 60068-2-30
  • Shock: IEC 60255-21-2
  • Freefall: IEC 60068-2-32
  • Vibration: IEC 60068-2-6
  • Hi-Pot: 1.5KV
Get In Touch

Contact Us

Have a question or need any assistance that should be answered by a professional? Contact us, and let our staff help you.