BR Series, 250A-1600A

BR Series, 250A-1600A2020-10-05T04:08:01+00:00

Busway SystemA Flexible, Safe, and Reliable Low Voltage Power Distribution Solution
With the brand vision “Smarter, Greener, Together,” Delta has utilized its industry-leading power electronics technology to develop the Busway BR Series for data center applications. Different from a conventional power cable system or sandwich busway solutions, Delta has adopted epoxy cast resin technology to significantly increase IP protection level, safety, and reliability. Delta’s solution is ideal for use in a variety of industries and climate conditions. The superior electrical and mechanical characteristics of resin minimize the Busway BR Series’ dimensions and simplify its structure. The Busway BR Series also has an extended product life cycle, increased reusability, and achieves significant energy savings for customers.

Specifications

busway-BR-series-specifications

Busway Rating : 250A
Model : BRC02
Rated voltage (AC/DC) : 1000V
Rated current : 250A
Frequency : 50/60 Hz
Resistance* : R20 : 213.0 μΩ/m; R85 : 267.4 μΩ/m; X50 : 138.1 μΩ/m; X60 : 165.7 μΩ/m
Impedance* : Z50 : 301.0 μΩ/m; Z60 : 314.6 μΩ/m

Conductor cross-section area : L1,L2,L3 : 72.5 mm2; N (100%) : 72.5 mm2; G (Internal) : 72.5 mm2
Busway Dimensions (h x w) : 58 x 117 mm

Busway Rating : 400A
Model : BRC04
Rated voltage (AC/DC) : 1000V
Rated current : 400A
Frequency : 50/60 Hz
Resistance* : R20 : 178.0 μΩ/m; R85 : 223.5 μΩ/m; X50 : 129.5 μΩ/m; X60 : 155.4 μΩ/m
Impedance* : Z50 : 258.3 μΩ/m; Z60 : 272.0 μΩ/m
Conductor cross-section area : L1,L2,L3 : 100 mm2; N (100%) : 100 mm2; G (Internal) : 50 mm2
Busway Dimensions (h x w) : 58 x 117 mm

Busway Rating : 600A
Model : BRC06
Rated voltage (AC/DC) : 1000V
Rated current : 600A
Frequency : 50/60 Hz
Resistance* : R20 : 106.3 μΩ/m; R85 : 133.5 μΩ/m; X50 : 112.3 μΩ/m; X60 : 134.8 μΩ/m
Impedance* : Z50 : 174.5 μΩ/m; Z60 : 189.7 μΩ/m
Conductor cross-section area : L1,L2,L3 : 145 mm2; N (100%) : 145 mm2; G (Internal) : 72.5 mm2
Busway Dimensions (h x w) : 58 x 117 mm

Busway Rating : 800A
Model : BRC08
Rated voltage (AC/DC) : 1000V
Rated current : 800A
Frequency : 50/60 Hz
Resistance* : R20 : 68.7 μΩ/m; R85 : 86.2 μΩ/m; X50 : 79.9 μΩ/m; X60 : 95.9 μΩ/m
Impedance* : Z50 : 117.5 μΩ/m; Z60 : 128.9 μΩ/m
Conductor cross-section area : L1,L2,L3 : 232 mm2; N (100%) : 232 mm2; G (Internal) : 116 mm2
Busway Dimensions (h x w) : 73 x 117 mm

Busway Rating : 1000A
Model : BRC10
Rated voltage (AC/DC) : 1000V
Rated current : 1000A
Frequency : 50/60 Hz
Resistance* : R20 : 50.2 μΩ/m; R85 :63.0 μΩ/m; X50 : 57.3 μΩ/m; X60 : 68.8 μΩ/m
Impedance* : Z50 : 85.2 μΩ/m; Z60 : 93.3 μΩ/m
Conductor cross-section area : L1,L2,L3 : 307.4 mm2; N (100%) : 307.4 mm2; G (Internal) : 153.7 mm2
Busway Dimensions (h x w) : 86 x 117 mm

Busway Rating : 1250A
Model : BRC12
Rated voltage (AC/DC) : 1000V
Rated current : 1250A
Frequency : 50/60 Hz
Resistance* : R20 : 34.7 μΩ/m; R85 :43.5 μΩ/m; X50 : 42.3 μΩ/m; X60 : 50.8 μΩ/m
Impedance* : Z50 : 60.7 μΩ/m; Z60 : 66.9 μΩ/m
Conductor cross-section area : L1,L2,L3 : 464 mm2; N (100%) : 464 mm2; G (Internal) : 232 mm2
Busway Dimensions (h x w) : 113 x 117 mm

Busway Rating : 1600A
Model : BRC16
Rated voltage (AC/DC) : 1000V
Rated current : 1600A
Frequency : 50/60 Hz
Resistance* : R20 : 23.0 μΩ/m; R85 :28.9 μΩ/m; X50 : 28.0 μΩ/m; X60 : 33.6 μΩ/m
Impedance* : Z50 : 40.2 μΩ/m; Z60 : 44.3 μΩ/m
Conductor cross-section area : L1,L2,L3 : 696 mm2; N (100%) : 696 mm2; G (Internal) : 348 mm2
Busway Dimensions (h x w) : 153 x 117 mm

* Impedance values are for busway operating at 20/85℃ temperature.

Plug-in Unit (Rv Type)

busway-BR-series-Plug-in-Unit-Rv-Series_en

Rating : 16A
Model : Rv-A3P16
Dimensions (H x D x W) : 275 x 165 x 100 mm
IP Rating : IP42
Weight : 3 kg

Rating : 32A
Model : Rv-A3P32
Dimensions (H x D x W) : 275 x 165 x 100 mm
IP Rating : IP42
Weight : 3 kg

Rating : 63A
Model : Rv-A3P63
Dimensions (H x D x W) : 275 x 165 x 100 mm
IP Rating : IP42
Weight : 3 kg

Rating : 125A
Model : Rv-A3P125
Dimensions (H x D x W) : 275 x 165 x 200 mm
IP Rating : IP42
Weight : 12 kg

Rating : 250A
Model : Rv-A3P250
Dimensions (H x D x W) : 275 x 165 x 300 mm
IP Rating : IP42
Weight : 20 kg

Rating : 400A
Model : Rv-A3P400
Dimensions (H x D x W) : 275 x 165 x 300 mm
IP Rating : IP42
Weight : 26 kg

Plug-in Unit (Rh Type)

busway-BR-series-Plug-in-Unit-Rh-Type

Rating : 16A
Model : Rh-A3P16
Dimensions (H x D x W) : 250 x 185 x 100 mm
IP Rating : IP42
Weight : 3 kg

Rating : 32A
Model : Rh-A3P32
Dimensions (H x D x W) : 250 x 185 x 100 mm
IP Rating : IP42
Weight : 3 kg

Rating :63A
Model : Rh-A3P63
Dimensions (H x D x W) : 250 x 185 x 100 mm
IP Rating : IP42
Weight : 3 kg

Rating : 125A
Model : Rh-A3P125
Dimensions (H x D x W) : 250 x 185 x 200 mm
IP Rating : IP42
Weight : 12 kg

Rating : 250A
Model : Rh-A3P250
Dimensions (H x D x W) : 250 x 185 x 300 mm
IP Rating : IP42
Weight : 20 kg

Rating : 400A
Model : Rh-A3P400
Dimensions (H x D x W) : 250 x 185 x 300 mm
IP Rating : IP42
Weight : 26 kg

End Feed Box

Rating : 250A
Catalogue Number : Rt-3P250
Dimensions (W x H x D) : 160 x 300 x 430 mm
Color : RAL7043
IP Rating : IP42
Weight : 15 kg

Rating : 400A
Catalogue number : Rt-3P400
Dimensions (W x H x D) : 160 x 300 x 430 mm
Color : RAL7043
IP Rating : IP42
Weight : 15 kg

Rating : 630A
Catalogue number : Rt-3P630
Dimensions (W x H x D) : 160 x 300 x 430 mm
Color : RAL7043
IP Rating : IP42
Weight : 17 kg

Rating : 1250A
Catalogue number : Rt-3P1250
Dimensions (W x H x D) : 250 x 300 x 430 mm
Color : RAL7043
IP Rating : IP42
Weight : 21 kg

Rating : 1600A
Catalogue number : Rt-3P1600
Dimensions (W x H x D) : 250 x 300 x 430 mm
Color : RAL7043
IP Rating : IP42
Weight : 28 kg

Get In Touch

Contact Us

Have a question or need any assistance that should be answered by a professional? Contact us, and let our staff help you.