RT Series 5/6/8/10 kVA Single Phase UPS, 15/20 kVA Three Phase UPS (new)

RT Series 5/6/8/10 kVA Single Phase UPS, 15/20 kVA Three Phase UPS (new)2020-10-04T17:21:56+00:00

Amplon RT SeriesA total solution for reliable power with high availability and performance
The Amplon RT Series 5-20kVA is an online double-conversion UPS that provides best-in-class designs in compact 2U size, high power density, system efficiency, and versatile configurations to fulfill customers’ requirements. Unity output power factor maximizes capacity for more critical loads, while outstanding energy savings can be achieved based on the AC-AC efficiency of up to 96.5% and 99% in ECO mode. In addition, RT Series 5-20kVA UPS is the first in the market that offers standard Li-ion external battery cabinets, which deliver better power density and sustainability. Along with the parallel capacity of up to four units, the new series is the ideal small power UPS for mission-critical applications, such as servers, data centers, telecommunications, and manufacturing.

Specifications

Model
RT-5K – Power Rating : 5kVA / 5kW
RT-6K – Power Rating : 6kVA / 6kW
RT-8K – Power Rating : 8kVA / 8kW
RT-10K – Power Rating : 10kVA / 10kW
RT-15K3P – Power Rating : 15kVA / 15kW
RT-20K3P – Power Rating : 20kVA / 20kW

Input
Voltage Range – RT-5/6/8/10K :
100 ~ 280V (Single phase, 2-wire + G)
100 ~ 175V with linear de-rating 50 ~ 100%
Voltage Range – RT-15/20K3P :
138 ~ 485V (Three phase, 4-wire + G)
138 ~ 305V with linear de-rating 40 ~ 100%
Frequency : 40 ~ 70 Hz
Power Factor : > 0.99 (full load)
iTHD : < 3%

Input connection – RT-5/6/8/10K : Input terminal x 1

Input connection – RT-15/20K3P : Input terminal x 1, Bypass Input terminal x 1

Output

Power Factor : Unity

Voltage – RT-5/6/8/10K : 200, 208, 220, 230, 240 Vac (Single phase)

Voltage – RT-15/20K3P : 380/400/415 Vac (Three phase), or 220/230/240 Vac (Single phase)

Frequency : 50/60Hz ±0.05Hz

Voltage Harmonic Distortion : ≤ 2% (linear load)

Overload Capability – RT-5/6/8/10K :

≤ 105%: continuous

106 ~ 125%, 5 min.

126 ~ 150%, 1 min. >

150%: 500ms
Overload Capability – RT-15/20K3P :
≤ 105%: continuous
106 ~ 125%: 2 min.
126 ~ 150%: 30 sec
> 150%: 200ms

Receptacle
Standard Runtime Model
RT-5/6K : C13x6, C19x2, Terminal x 1, Load bank: C19x1
RT-8/10K : C13x6, C19x4, Terminal x 1, Load bank: C19x1

Extended Runtime Model
RT-5/6/8/10K : Terminal x 1, Load bank: Terminal x 1
RT-15/20K3P : Terminal x 1

Efficiency
AC-AC
RT-5/6/8/10K : Up to 95.5%
RT-15/20K3P : Up to 96.5%
ECO Mode : Up to 99%

Battery Voltage
Standard Runtime Model
RT-5/6K : 192 Vdc
RT-8/10K : 240 Vdc

Extended Runtime Model
RT-15/20K3P : ±144 Vdc*, ±192 ~ 264 Vdc
Charger Current
Standard Runtime Model
RT-5/6K : 1A (default)
RT-8/10K : 1.5A (default)
RT-15/20K3P : Up to 8A
Extended Runtime Model : Up to 8A

Typical Backup Time (Run Time Table)
Standard Runtime Model – 75% load
RT-5K : 7.5 min.
RT-6K : 5.5 min.
RT-8K : 9 min.
RT-10K : 6 min.
RT-15/20K3P : Depending on different configurations required by customers

Standard Runtime Model – Full load
RT-5K : 5 min.
RT-6K : 3 min.
RT-8K : 5 min.
RT-10K : 3.5 min.
Extended Runtime Model : Depending on different configurations required by customers

Audible Noise
RT-5/6K : 48 dB
RT-8/10K : 50 dB
RT-15/20K3P : 54 dB

Display : Graphical and multi-lingual LCD

Communication Interfaces : MINI Slot x 1, Parallel Port** x 2, USB Port x 1, RS232 Port*** x 1, RS485 Port x 1, REPO/ROO Port x 1, Dry Contact x 4

Dimensions (W x D x H)
Standard Runtime Model
RT-5/6K : 440 x 665 x 176 mm
RT-8/10K : 440 x 750 x 218 mm

Extended Runtime Model
RT-5/6K : 440 x 430 x 88.2 mm
RT-8/10K : 440 x 565 x 88.2 mm
RT-15/20K3P : 440 x 760 x 88.2 mm

Weight
Standard Runtime Model
RT-5/6K : 54 kg
RT-8/10K : 85.5 kg

Extended Runtime Model
RT-5/6K : 10.9 kg
RT-8/10K : 15.2 kg
RT-15K3P : 22.5 kg
RT-20K3P : 22.5 kg

Environment
Operating Temperature : 0 ~ 55° C****
Relative Humidity : 5 ~ 95% (non-condensing)

* De-rating to 70% load
** Only applicable to RT 5-10kVA Extended Runtime Model and RT 15/20kVA
*** Not applicable to RT 20kVA
**** When the operating temperature is at 40 ~ 55° C, the UPS will be de-rated to 75% of its capacity

All specifications are subject to change without prior notice.

Run Time

Standard Model
Standard Model

Extended Model
Standard Model

Get In Touch

Contact Us

Have a question or need any assistance that should be answered by a professional? Contact us, and let our staff help you.