DPS Series UPS, Three Phase, 300/400/500/600/1000/1200 kVA

DPS Series UPS, Three Phase, 300/400/500/600/1000/1200 kVA2021-07-08T11:31:22+00:00

Ultron DPS seriesThe Next Generation UPS Answering the Demand of Large Data Centers and Colocations
Delta’s superior Ultron DPS series 300 – 1200kVA UPS supports unity output power factor to deliver up to 10 MW power capacity to meet the demands for large data centers and colocations that require higher power capacity. The Ultron DPS series guarantees the highest level of system reliability and resiliency by supporting self-detection of key components with pre-warning function, multilayered redundancy design, and complete power rating coverage. Moreover, the DPS series supports advanced manageability. Key environment parameters, and event analysis can all be monitored via local 10” LCD monitor and remotely. Along with optional battery management software, the DPS series enables users to achieve predictive maintenance and minimize system downtime, while lowering the total cost of ownership (TCO).

Ultron DPS series

Specifications

Model
DPS-300K Power Rating : 300kVA / 300kW
DPS-400K Power Rating : 400kVA / 400kW
DPS-500K Power Rating : 500kVA / 500kW
DPS-600K Power Rating : 600kVA / 600kW
DPS-1000K Power Rating : 1000kVA / 1000kW
DPS-1200K Power Rating : 1200kVA / 1200kW

Input
Nominal Voltage : 220/380V, 230/400V, 240/415V (3-phase, 4-wire + G)
Voltage Range : 176/304~276/478 VAC (full load)
Current Harmonic Distortion : <3% (with Full Linear Load); <5% (with Full Non-linear Load) Power Factor : > 0.99
Frequency Range : 40 ~ 70 Hz

Output
Voltage : 220/380V, 230/400V, 240/415V (3-phase, 4-wire + G)
Voltage Harmonic Distortion : <1.5% (Linear Load); <5% (Non-linear Load) Voltage Regulation : ±1 (static); ±5 (dynamic) Output Power Factor : 1 Frequency : 50/60Hz (Auto-Selectable) Overload Capability : ≦ 125%: 10 min; ≦ 150%: 1 min; >150%: 1 sec

Display : 10” Color Touch Panel

Interface
Standard : RS232, Parallel port, USB, Modbus RS485, Input dry contact, Output dry contact, SNMP card inbuilt in touch screen
Optional : Relay I/O card, Battery cabinet temperature sensor cable

Conformance
Safety : CE

Efficiency
AC-AC Mode : Up to 96.5%
ECO Mode : 99%

Battery
Type : VRLA, LiB
Charge Current
DPS-300K : 90A
DPS-400K : 120A
DPS-500K : 150A
DPS-600K : 180A
DPS-1000K : 300A
DPS-1200K : 360A
Battery Quantity : 30 – 46 pcs

Environment
Operating Temperature : 0 ~ 40℃
Relative Humidity : 0 ~ 95% (non-condensing)
Audible Noise : <80 dB
IP Protection : IP 20

Others
Parallel Redundancy and Expansion : Maximum 8 units
Emergency Power Off : Remote and local

Physical
Dimensions (W x D x H)
DPS-300K : 600* x 900 x 2000 mm
DPS-400K / DPS-500K / DPS-600K : 1200* x 900 x 2000 mm

Weight
DPS-300K : 515kg
DPS-400K : 700kg
DPS-500K : 811kg
DPS-600K : 970kg
DPS-1000K : 1870kg
DPS-1200K : 2000kg

* The width is for the cabinet which has four inbuilt switches.
All specifications are subject to change without prior notice.