- Data acquisition equipment connected to cloud servers.
- Supports a two-way data collection channel between the device and the cloud
- Sets up a secure tunnel between the user and the remote device via the cloud server, without the need of additional VPN servers
- Supports MODBUS TCP and MODBUS RTU/ASCII protocols
- Flexible connection method over WAN ports, e.g. static IP, DHCP client and more
- Various peripheral interfaces include RS-485, RS-232 and 4 LAN ports
- Built-in RTC and supports NTP time synchronization over a network
- Firewall functions: Stateful Packet Inspection (SPI), Prevent Denial of Service (DoS) attacks, NAT, port triggering, port mapping, IP address filter, MAC address filter, URL filter
- Supports TCP/IP, UDP, ICMP, DHCP, HTTP, DNS and SSH protocols
- Scheduled jobs are available
- Device configurations can be exported and imported.
- Network data flow statistics
- Networking failure diagnostics
- Device and PLC interlocking
- Custom alarm conditions with email alerts
- Supports Android and iOS devices on-line monitoring

Specifications
TECHNOLOGY
Standard Compliance
- IEEE 802.3 10Base-T
- IEEE 802.3u 100Base-T(X)
INTERFACE
Fast Ethernet
- RJ45 Ports:
WAN: 1 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
LAN: 4 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
Serial Communication
- Serial Ports : 1 RS-232(DB9 male), 1 RS-485( Terminal block), 15KV isolation protection
- Baud Rate: 2400bps to 115200bps
- Data Bits: 7, 8
- Parity: None, Even, Odd
- Stop Bits: 1, 2
- Flow Control: RTS/CTS(RS-232 only), XON/XOFF
- RS-232: TxD, RxD, RTS, CTS, GND
- RS-485: D+, D-, GND
LEDs
- Device: PWR, SD, Ready
- RJ45 Ports: 100M, LINK/ACT
- Serial Ports: RS-232, RS-485
Reset Button
- 1set
MANAGEMENT
Cloud Service
- DIACloud
Software
- SSH, DNS, HTTP, TFTP, DHCP Server/Client, Telnet, Syslog, MODBUS TCP, NTP, MODBUS RTU/ASCII
Security
- MAC/IP/URL filtering, SSH, SPI, Prevent denial of service (DoS) attacks, Port triggering, Port mapping
Virtual COM Drivers
- Windows XP, Windows Vista (32/64 bits), Windows 7 (32/64 bits)
Configuration
- Web Browser, DIACom, Android APP, iOS APP
POWER REQUIREMENTS
- Input Voltage: 9to 40VDC, 2 pin terminal block input
- Input Current: 0.53A Max.
- Overload Current Protection: Present, Max. Input current 1.5A
- Reverse Polarity Protection: Not Present
PHYSICAL
- Housing: IP30 metal case
- Dimensions: 145.3 mm(H) x 45 mm(W) x 112.3 mm (D)
- Weight: 308g
- Installation: Industrial DIN-Rail and Wall mounting
ENVIRONMENTAL LIMITS
- Operating Temperature : -20℃ to 70℃(-4℉ to 158℉)
- Storage Temperature: -40℃ to 85℃(-40℉ to 185℉)
- Ambient Relative Humidity: 5% to 95%(non-condensing)
APPROVALS
- Safety: UL 60950-1, EN 60950-1
- EMI: FCC 47 CFR Part 15 Subpart B Class A, EN 55022
- EMS( EN 55024): IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8